Emulations and functions
RS232 (TTL)
It is possible to use up to 2 independent,
individually operating serial interfaces. Each
interface can be individually set and it is
possible to transfer data rates of up to
2.500.000 bauds. Furthermore, it is possible
to additionally set emulations such as
modem, Auto-Connect, Connect-On-Data,
TCP / UDP client using up to 10 parallel
connections, TCP/UDP server, tunnel mode
with transfers of the signal modes as well as
settings, E-Mail client including sending and
receiving of e-mails.
RS485 (TTL)
It is possible to use up to 2 independently
operating RS485 interfaces. This mode also
supports so-called 2-wire components, e.g.
the MAX3072E, since it does not possess a
proper control wire. Each interface can be
individually set and it is possible to transfer
data rates of up to 2.500.000 bauds.
Furthermore, it is possible to additionally set
emulations such as modem, AutoConnect,
Conntect-On-Data, TCP/UDP client using
up to 10 parallel connections, TCP/UDP
server, tunnel mode with transfer of the
signal modes as well as settings, E-Mail
client including sending and receiving of e-
mails.
I2C
It is possible to use up to 2 independently
operating I2C interfaces. A data mode has
also been implemented to achieve a
maximum of flexibility. The interface can be
individually set up and it is possible to
transfer data rates of up to 2.500.000
bits/sec. Furthermore, you can additionally
set emulations such as modem,
AutoConnect, Conntect-On-Data,
TCP/UDP client using up to 10 parallel
connections, TCP/UDP server, E-Mail client
including sending and receiving of e-mails.
SPI
It is possible to use up to 2 independently
operating SPI interfaces in the master or
slave mode. Each interface can be set up
individually and it is possible to transfer data
rates of up to 25MBit(Master) and
2.5Mbit(Slave). Furthermore, it is possible to
additionally set emulations such as
AutoConnect, Conntect-On-Data, TCP/UDP
client using up to 10 parallel connections,
TCP/UDP server, E-Mail-Client including
sending and receiving of e-mails.
By making adjustments in the setup, the SPI
interface can directly operate SD cards, DF
cards or Data-Flash components. An
implemented Flash-File system with
FAT12/16/32 structure supports the FTP to
save data on it or to read data from it. Now it
is possible to save your own homepage or
JAVA applet in order to present a proper and
individual look to the customers via the WEB
server.
SD cards:
- Up to 4 GByte
- FAT12/16/32
- PC-compatible
DF cards / components:
- Up to 4 GByte
- FAT12/16/32
- AT45DB011B,AT45DB021B
AT45DB041B,AT45DB081B
AT45DB0161B,AT45DB0321B
AT45DB0642, AT45DB1282
will be directly identified.
The SPI interface can also directly control as
SPI display, e.g. the EA DOGM162B-A, which
you can directly use via TCP/IP.
TTL IO
It is possible to directly control up to 14 pins
via two interfaces. To do so, there is a proper
control mode which can read the signals,
switch them on or off. A tunnel mode allows
the automatic transfer of the signal modes.